Kinova Gen3 + Robotiq 2F-85 · 7 axes · reach 0.902 m · payload 4 kg
Pick and place — find by itself at random positions
Trial 1 · Success
25 trials
Pass
25/25
Successes / measured
Reason
25 of 25 measured trials succeeded. The lower bound of the 95% confidence interval of the success rate, 86.6%, is above the pass threshold of 80%, so the result is Pass.
Success rate 95% confidence interval verdict
Rule version v2.3b-2026-10-04 · measured 2026-10-11
Verdict evidence
Measured values and criteria
Item
Measured value
Criterion
Results
Successes
25 / 25
Successes among measured trials
For reference
Success rate
100.0%
Point estimate (for reference)
For reference
Success rate 95% confidence interval
86.6% ~ 100.0%
Lower bound > 80.0% = Pass · upper bound < 40.0% = Fail
Pass
Excluded from measurement
0 / 25
None
Excluded from the count (counted as neither failure nor success)
Minimum measured trials
25
4 or more
Met
Same test, 5 robots
95% confidence interval of the success rate (bar) and the success rate (dot). Dashed line: pass line 80% — Pass if the lower bound of the interval is above this line.
50%
60%
70%
80%
90%
100%
Test conditions and limits
Measured
Placement
Trial
Robot control
Robot model
Test environment
What this result does not show
- Finding objects outside the defined range
- Re-recognizing object pose in the hand
- Grasp detection at the level of a real robot force sensor
- Real robot performance — these are simulation results and do not replace physical tests
- Performance ranking of robot manufacturers — this is a baseline produced with the imSim baseline controller
- Official third-party approval — this is self-scoring in an in-house test environment
Also recorded
Not used for the verdict
Pass and fail are decided only by the evidence above. The items below are recorded for every trial and published as measured.
No collision other than with the work object
Failed 2 · Passed 23 / evaluated 25